The Complete Line Of Humidifiers From GENERALAire


FEATURES,
SPECIFICATIONS
AND BENEFITS
 MODEL 1042LH  MODEL 1099LH  MODEL1137
APPLICATION Flow-through humidifier that’s ideal for most homes. Installs on vertical warm air supply or cold air return plenum. Highest capacity flow-through humidifier for large homes. Installs on vertical warm air supply or cold air return plenum. Flow-through humidifier that’s ideal for most homes. No by-pass required. Installs on vertical warm air supply plenum.
UNIT SIZE  15" wide x 11-1/2" high x 9" deep  16" wide x 16" high x 11" deep  16" wide x 14" high x 10" deep
PLENUM OPENING  10-1/4" wide x 9-1/2" high  13-1/4" wide x 9-1/4" high  15" wide x 9-1/2" high
BYPASS DUCT  6" diameter (collar supplied)  7" diameter (collar supplied)  N/A
EVAPORATIVE OUTPUT CAPACITY @ .20"
PRESSURE DIFFERENTIAL
(except 747 rated at 800 FPM duct velocity)
ABOVE AT STANDARD INDUSTRY RATING CONDITIONS
Temp°F
GPD
Temp°F
GPD
80°
8.0
140°
19.2
100°
12.2
160°
23.2
120°
16.4
   
Temp°F
GPD
Temp°F
GPD
80°
10.7
140°
23.1
100°
14.6
160°
27.2
120°
19.3
   
Temp°F
GPD
Temp°F
GPD
80°
10.4
140°
21.3
100°
14.4
160°
25.3
120°
17.7
   
Note: 140° hot water supplied to the humidifier in heat pump applications will increase capacity 4.3 GPD.
EVAPORATIVE PRINCIPLE GENERALAire humidifers are 100% evaporative, adding moisture in the form of water vapor only. They are clean operating. The nuisance of airborne water droplets or mineral dust is avoided. Forced warm air heating systems create a pressure differential that diverts some heated air to the humidifier through a bypass duct. There, the warm air absorbs moisture from a water-soaked evaporator pad and then rejoins the primary warm air stream for distribution throughout the living area. A solenoid valve and patented distribution tray meter and disperse water uniformly across the evaporator pad. Unevaporated water drains from the unit. Forced warm air heating systems create a pressure differential that diverts some heated air to the humidifier through a bypass duct. There, the warm air absorbs moisture from a water-soaked evaporator pad and then rejoins the primary warm air stream for distribution throughout the living area. A solenoid valve and uniquely designed distribution tray meter and disperse water uniformly across the evaporator pad. Unevaporated water drains from the unit. A motor-driven fan directs a portion of the heated air through the water-soaked evaporator pad. The warm air absorbs moisture and returns through internal baffles to the primary warm air stream for distribution throughout the living area. A solenoid valve and patented distribution tray meter and disperse water uniformly across the evaporator pad. Unevaporated water drains from the unit.
EVAPORATIVE MEDIA 990-13 Evaporator Pad. Designed for high output with minimal hard water scale accumulation. UL listed. 1099-20 Evaporator Pad. Designed for high output with minimal hard water scale accumulation. UL listed. 990-13 Evaporator Pad. Designed for high output with minimal hard water scale accumulation. UL listed.
WATER SUPPLY Dependable stainless steel solenoid valve with monel wire mesh filter that protects the precision machined Teflon flow-control orifice. Saddle valve supplied. Use 1/4" copper tubing. Dependable stainless steel solenoid valve with monel wire mesh filter that protects the precision machined Teflon flow-control orifice. Saddle valve supplied. Use 1/4" copper tubing. Dependable stainless steel solenoid valve with monel wire mesh filter that protects the precision machined Teflon flow-control orifice. Saddle valve supplied. Use 1/4" copper tubing.
DRAIN CONNECTION High capacity 5/8" drain and hose prevents clogging. Includes 15' vinyl hose except recircating models. High capacity 5/8" drain and hose prevents clogging. Includes 15' vinyl hose except recircating models. High capacity 5/8" drain and hose prevents clogging. Includes 15' vinyl hose except recircating models.
RANGE OF MODELS 1042 – line voltage
1042-L – low voltage
1042-LH – low voltage w/H-86 Humidistat
1042-R – recirculating, no drain required, with time-tested Model 975 Recirculating Pump
1099 – line voltage
1099-L – low voltage
1099-LH – low voltage w/H-86 Humidistat
1099-R – recirculating, no household drain required, with time-tested Model 975 Recirculating Pump
1137 – line voltage
1137-R – recirculating, no household drain required, with time-tested Model 975 Recirculating Pump
ELECTRICAL 1042 – 115 V. 60 Hz.
1042-L – 24 V. 60 Hz.
1042-LH – 24 V. 60 Hz.
1042-R – 115 V. 60 Hz.
(L/LH models – transformer supplied)
1099 – 115 V. 60 Hz.
1099-L – 24 V. 60 Hz.
1099-LH – 24 V. 60 Hz.
1099-R – 115 V. 60 Hz.
(L/LH models – transformer supplied)
1137 – 115 V., 1.0 Amp, 60 Hz.
1137-R – 115 V., 1.6 Amp, 60 Hz.
(Hook-up wire supplied)
CONTROLS Manual air shutter for summer shut-off affords some control of humidifier output. Model 1042 LH includes GENERALAire H-86 wall/duct mount humidistat. Manual air shutter for summer shut-off affords some control of humidifier output. Model 1099 LH includes GENERALAire H-86 wall/duct mount humidistat. GENERALAire H-86 wall/duct mount humidistat.
CONSTRUCTION,
MATERIALS AND STYLING
Attractive cabinet made from durable,non-corrosive, high temperature materials for long service life. Large, streamlined cabinet made from durable, non-corrosive, fiberglass-reinforced polyester for long service life. Attractive cabinet made from durable, non-corrosive, high temperature materials for long service life.
VERSATILITY Right or left hand bypass installation. May be installed on up-flow, counter-flow or horizontal furnaces or air handlers. Right or left hand bypass installation. May be installed on up-flow, counter-flow or horizontal furnaces or air handlers. Single plenum design fits minimum space situations. Motor-driven fan eliminates bypass pipe. May be installed on up-flow or horizontal furnaces or air handlers.
SERVICEABILITY Thumbscrews allow easy access to distribution trough, drain pan and evaporative pad for quick, easy cleaning and service. Slide clips allow quick access to the distribution trough, drain pan and evaporative pad for quick, easy cleaning and service. Thumbscrews allow easy access to the distribution trough, drain pan and evaporative pad for quick, easy cleaning and service. Simple, removable back cover allows easy access to electrical components.
EASY INSTALLATION – GENERALAire humidifers are specially designed for fast, easy installation Most important components are included. Outboard and keyholed screw holes and simple thumbscrew assembly speeds installation. Patented water distribution tray reduces need for critical leveling. Most important components are included. Outboard screw holes and simple slide clip assembly speeds installation. Patented water distribution tray reduces need for critical leveling. Most important components are included. Outboard screw holes and simple thumbscrew assembly speeds installation. Patented water distribution tray reduces need for critical leveling. Guarded fan blade assures safety.
 

 